91
⿎
Counter reset : CTR
Resets the current counter value to the initial value.
• Counter reset
STX CTR S
[Counter 0 to 7]
8-byte
(Check sum) Delimiter
Name
Data length
[byte]
Description Remarks
Counter 0 1
“0”: reset OFF
“1”: reset ON
Counter 4 to counter 7 are common counters.
Counter 1 1
Counter 2 1
Counter 3 1
Counter 4 1
Counter 5 1
Counter 6 1
Counter 7 1
⿎
Expiry date/time condition : LMT
Sets the expiry date/time condition.
Expiry date/time can be set within the range from January 1, 1980 to December 31, 2099.
• Setting / Readout data of expiry date/time condition
STX LMT
Sub
command
[Expiry No.] [Expiry]
[Reference unit] [Start date]
7-byte
(Check sum) Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
• Readout request of expiry date/time Condition
STX LMT R
[Expiry No.]
1-byte
(Check sum) Delimiter
Name Data length [byte] Description Remarks
Expiry No. 1 “1”–“8” “5”–“8”: common expiry date/time
Expiry 4 “-999”–“+999”
Reference unit 1
“0”: year
“1”: month
“2”: day
“3”: hour
“4”: minute
Start date 1
“0”: Today not included
“1”: Today included
Possible to be set only when the reference
unit is set to “year” or “month”. Indicating if
the date of “today” is included or not.