EasyManua.ls Logo

Panasonic MCDLT35BM - Connector and Terminal Block Details; Power Connector Pin Assignments

Panasonic MCDLT35BM
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. SX-DSV03335 - 34-
R2.0 Industrial Device Solution Business Unit, Panasonic Corporation
7. Configuration of connectors and terminal blocks
7-1 Power connectors XA , XB , XC , XD and terminal block
Size A, B 100 V / 200 V
Pin No.
Symbol
Name
Description
XA
5
L1
Main power input
terminal
100 V
Single-phase 100 - 120 V
+ 10 %
50/60 Hz
- 15 %
For single-phase, the connector should be connected to the L1 and L3 terminals.
4
L2
200 V
Single-phase/3 phase 200 - 240 V
+ 10 %
50/60 Hz
- 15 %
3
L3
For single-phase, the connector should be connected to the L1 and L3 terminals.
2
L1C
Control power input
terminal
100 V
Single-phase 100 - 120 V
+ 10 %
50/60 Hz
- 15 %
1
L2C
200 V
Single-phase 200 - 240 V
+ 10 %
50/60 Hz
- 15 %
XB
6
P
Regenerative resistor
connecting terminal
To use an external regenerative resistor (customer prepared), connect an external
regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor.
For details, refer to "Technical Refarence - Functional Specification-"
Do not connect anything to the N terminal.
5
N
4
B
3
U
Motor output terminal
Connect each phase of the motor wiring.
U: U phase, V: V phase, W: W phase
2
V
1
W
Erath
Earth terminal for grounding
*Tighten the Earth screw with a torque of M4: 1.0 to 1.2 N · m.

Table of Contents

Related product manuals