EasyManua.ls Logo

Panasonic MCDLT35BM - Feedback Scale Output Signal; Position Comparison Output Signal

Panasonic MCDLT35BM
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. SX-DSV03335 - 44-
R2.0 Industrial Device Solution Business Unit, Panasonic Corporation
Feedback scale output signal / Position comparison output signal
Name
Symbol
Pin No.
Description
Input /output
signal Interface
A-phase output
Position
comparison
Output 1
OA+/
OCMP1+
17
Differential output of divided feedback scale signal or external
scale signal (A Bphase). (RS422 compatible)
The division ratio can be set by the parameters.
The ground of the line driver for the output circuit is connected
to the signal ground (GND), and kept non-insulated.
Maximum output frequency is 4 Mpps (after multiplied by 4).
It can be used as position compare output by parameter setting.
For details, refer to "Technical Reference -Functional
Specification-"
This differential signal should be received by a line receiver
(AM26C32 or equivalent). Connect a terminating resistor
(approx. 330 Ω) between the line receiver inputs.
For wiring, use shielded twisted pair cable, please connect
shielded wire to connector shell.
Do-1
OA-/
OCMP1-
18
B-phase output/
Position
comparison
Output 2
OB+/
OCMP2+
20
OB-/
OCMP2-
19
Position
comparison
Output 3
OCMP3+
21
OCMP3-
22
Signal
Ground
GND
16
Signal ground
Be sure to connect the line receiver ground to this terminal.
-
Other
Name
Symbol
Pin No.
Description
Input / output
signal interface
Reserved
-
14,15
23,24
Do not connect anything to this connector.
-
Frame
Ground
FG
Shell
Connected to the earth terminal in the servo driver.
-