Monitor Lamp indicators
76
- ENGLISH
Maintenance
J
TEMP indicator
Lamp
indication
Information Check point Remedial measure
Lighting in red
Warm-up status
Did you turn on the power when
z
the ambient temperature was
lower than approx. 0 °C (32 °F)?
Wait about 5 minutes in the current
z
status.
Install the unit in a location having
z
an ambient temperature from 0 °C
(32 °F) - 45 °C (113 °F).
High temperature
inside. (WARNING)
Check the ventilation port is
z
blocked.
Is the room air temperature too
z
high?
Is the lter indicator lighted?
z
Remove the object that is blocking
z
the ventilation port.
Move the projector to a temperature
z
of 0 °C (32 °F) - 45 °C (113 °F) and
the humidity of 20 % to 80 % (no
condensation).
Turn off the MAIN POWER switch
z
using the procedure on page 33 and
replace the ACF unit.
Blinking in red
(once)
High temperature
inside.
(
Power ON condition
)
Blinking in red
(twice)
High temperature
inside.
(Standby condition)
Blinking in red
(3 times)
Cooling fan has
been stopped.
—
Turn off the MAIN POWER switch
z
using the procedure on page 33 and
consult the dealer.
Note
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
z