-72-
Electrical Adjustments
Group/
Item
Item Name Function Range Initial Note
2 GAIN AREA H START White Level Acq. Area H Start 0 - 1000 25
3 GAIN AREA V START White Level Acq. Area V Start 0 - 1000 500
4 Image AREA H WIDTH Black/White Level Area Width 0 - 4095 13
5 Image AREA V HEIGHT Black/White Level Area Height 0 - 4095 9
6 OFFSET Target Black Level Adj target 0 - 1023 20
7 OFFSET Tolerance Black Level Adj telerance 1 - 1023 1
8 GAIN Target White Level Adj target 0 - 1023 955
9 GAIN Tolerance White Level Adj telerance 1 - 1023 1
10 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 2
Group
262
Auto Calibration (CVBS/
SVIDEO)
PW392-AFE MDL <10bits>
0 Y Image Area Start X Y Image Area H Start 0 - 1000 20
1 Y Image Area Start Y Y Image Area V Start 0 - 1000 200
6 Image Area H WIDTH Image Level Acq. Width 0 - 4095 8
7 Image Area V HEIGHT Image Level Acq. Height 0 - 4095 9
8 Y Target Level Y Level Adj target 0 - 1023 875
11 Gain Tolerance Level Adj Tolerance 1 - 255 1
12 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 2
Group
264
Auto Calibration (YCbCr) PW392-AFE MDL <10bits>
0 Y-OFFSET AREA H START Y - Offset Acq Area H Start 0 - 1000 925
1 Y-OFFSET AREA V START Y - Offset Acq Area V Start 0 - 1000 500
2 CB - OFFSET AREA H START CB - Offset Acq. Area H Start 0 - 1000 925
3 CB - OFFSET AREA V START CB - Offset Acq. Area V Start 0 - 1000 500
4 CR - OFFSET AREA H START CR - Offset Acq. Area H Start 0 - 1000 925
5 CR - OFFSET AREA V START CR - Offset Acq. Area V Start 0 - 1000 500
6 Y - GAIN AREA H START 0 - 1000 50
7 Y - GAIN AREA V START 0 - 1000 500
8 CB - GAIN AREA H START 0 - 1000 800
9 CB - GAIN AREA V START 0 - 1000 500
10 CR - GAIN AREA H START 0 - 1000 700
11 CR - GAIN AREA V START 0 - 1000 500
12 Image AREA H WIDTH YCBCR Level Acq. Width 0 - 4095 13
13 Image AREA V HEIGHT YCBCR Level Acq. Height 0 - 4095 9
14 Y - OFFSET TARGET 0 - 1023 4
15 CB OFFSET TARGET 0 - 1023 512
16 CR OFFSET TARGET 0 - 1023 512
17 Y - GAIN TARGET 0 - 1023 810
18 CB - GAIN TARGET 0 - 1023 894
19 CR - GAIN TARGET 0 - 1023 894
20 OFFSET Tolerance OFFSET Adj Tolerance 1 - 255 1
21 GAIN Tolerance GAIN Adj Tolerance 1 - 255 1
22 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 2
Group
275
DLV Illuminance sensor
0
Illuminanc e m easure va l ue
(ADC)
Illuminance value [ADC] (display only) 0 - 1023 -
1 Illuminance value (Lx) Illuminance value [Lx] (display only) 0 - 1023 -
2 DLV- Level DLV-Level value (display only) 0 - 3 -
3 Value L1 (bed position)
Level1->0 switch reference value
(illuminance value [ADC]))
0 - 1023 115
4 Value L2 (bed position)
Level0->1 switch reference value
(illuminance value [ADC]))
0 - 1023 214
5 Value L3 (bed position)
Level2->1 switch reference value
(illuminance value [ADC]))
0 - 1023 276
6 Value L4 (bed position)
Level1->2 switch reference value
(illuminance value [ADC]))
0 - 1023 372
7 Value L5 (bed position)
Level3->2 switch reference value
(illuminance value [ADC])
0 - 1023 512
8 Value L6 (bed position)
Level2->3 switch reference value
(illuminance value [ADC]))
0 - 1023 601
9 Value L1 (ceiling)
Level1->0 switch reference value
(illuminance value [ADC]))
0 - 1023 26
10 Value L2 (ceiling)
Level0->1 switch reference value
(illuminance value [ADC]))
37
0 - 1023
11 Value L3 (ceiling)
Level2->1 switch reference value
(illuminance value [ADC]))
51
0 - 1023
12 Value L4 (ceiling)
Level1->2 switch reference value
(illuminance value [ADC]))
71
0 - 1023
13 Value L5 (ceiling)
Level3->2 switch reference value
(illuminance value [ADC]))
116
0 - 1023
14 Value L6 (ceiling)
Level2->3 switch reference value
(illuminance value [ADC]))
155
0 - 1023