Chapter 4 Settings — [PROJECTOR SETUP] menu
164 - ENGLISH
[AC VOLTAGE] Displays the input supply voltage.
[ON COUNT] [POWER ON TIMES] Displays the number of times the power is turned on.
[UPGRADE KIT]
[ET-UK20]
Displays the activation status by the Upgrade Kit (Model No.:
ET-UK20).
[ET-CUK10]
Displays the activation status by the Auto Screen Adjustment
Upgrade Kit (Model No.: ET-CUK10).
[ET-NUK10]
Displays the activation status by the NFC Upgrade Kit (Model No.:
ET-NUK10).
Or, displays the status of the NFC function.
[ACTIVATED]: The NFC function can be used.
[NOT ACTIVATED]: The NFC function cannot be used.
[SLOT]
Displays the product model number of the Interface Board installed in the slot.
Also, the rmware version is displayed after the product model number.
[OPERATING MODE]
Displays the setting value of the [PROJECTOR SETUP] menu → [OPERATION SETTING] →
[OPERATING MODE].
[NORMAL] Displays the runtime of the light source with [OPERATING MODE] set to [NORMAL].
[ECO] Displays the runtime of the light source with [OPERATING MODE] set to [ECO].
[QUIET]
*2
Displays the runtime of the light source with [OPERATING MODE] set to [QUIET]/[QUIET1].
[QUIET1]
*3
[QUIET2]
*3
Displays the runtime of the light source with [OPERATING MODE] set to [QUIET2].
[USER1] Displays the runtime of the light source with [OPERATING MODE] set to [USER1].
[USER2] Displays the runtime of the light source with [OPERATING MODE] set to [USER2].
[USER3] Displays the runtime of the light source with [OPERATING MODE] set to [USER3].
[CONSOLIDATED RUNTIME]
*4
Converts the total runtime of the light sources with [OPERATING MODE] set to each item into the
time used with the [NORMAL] setting.
The consolidated runtime is used for a rough indication about when to perform maintenance when the
projector is used in combination of each item in [OPERATING MODE].
[SIGNAL INFORMATION]
[INPUT]
Displays the input terminal used for the projected image.
Displays the representative input terminal when one image is
displayed with multiple input signals.
[SIGNAL FORMAT] Displays the format of the input signal.
[LINK]
Displays the [SDI LINK] setting.
Displays the determination result of the signal when set to [AUTO].
[SAMPLING]
Displays the sampling information and the color format of the input
signal.
[BIT DEPTH] Displays the gradation of the input signal.
[SIGNAL LEVEL] Displays the signal level of the input signal.
*1 The temperature status is indicated with text color (green/yellow/red) and bar scale. Use the projector within the range that the indication is
green.
*2 Only for PT-RCQ80
*3 Only for PT-RCQ10
*4 [CONSOLIDATED RUNTIME] can be obtained with the following calculation formula. Values obtained by the calculation formula contain a
slight error.
Conversion formula for [CONSOLIDATED RUNTIME]
A x 1.0 + B x 0.8
f A: Runtime of the light source with [OPERATING MODE] set to [NORMAL], [QUIET], [QUIET1], [QUIET2], [USER1], [USER2], or [USER3]
f B: Runtime of the light source with [OPERATING MODE] set to [ECO]
r [DETAILED INFORMATION]
[INPUT] Displays the input terminal used for the projected image.
[SIGNAL FORMAT] Displays the format of the input signal.
[SIGNAL FREQUENCY] Displays the frequency of the input signal.
[SCAN TYPE] Displays the scan type of the input signal.
[TOTAL DOTS] Displays the total dot count of the input signal.
[DISPLAY DOTS] Displays the number of input signal display dots.
[TOTAL LINES] Displays the total line count of the input signal.
[DISPLAY LINES] Displays the number of input signal display lines.
[SAMPLING] Displays the sampling information and the color format of the input signal.
[BIT DEPTH] Displays the gradation of the input signal.
[SIGNAL LEVEL] Displays the signal level of the input signal.