EasyManua.ls Logo

Panasonic PT-RCQ10

Panasonic PT-RCQ10
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7Appendix — Technical information
ENGLISH - 233
Class
Command
Control details
Parameter/response
string
Remark
2 INNM ?
Input terminal name
query
31 / DVI-D
Returns input terminal name.
32 / HDMI
33 / DIGITAL LINK
34 / SDI
35 / SLOT-1
SLOT-1 (name of the input 1 of the Interface Board installed in
the slot)
36 / SLOT-2
SLOT-2 (name of the input 2 of the Interface Board installed in
the slot)
37 / SLOT-3
SLOT-3 (name of the input 3 of the Interface Board installed in
the slot)
38 / SLOT-4
SLOT-4 (name of the input 4 of the Interface Board installed in
the slot)
2 IRES ?
Input signal resolution
query
AAAAxBBBB
AAAA: Horizontal resolution
BBBB: Vertical resolution
2 RRES ?
Recommended
resolution query
1920 x 1200 Returns display resolution.
2
FREZ Freeze control 0 Freeze clear
FREZ ? Freeze status query 1 Freeze (stop)
2 POWR
Cooling notication 0 Noties when the power is turned off.
Warmup notication 1 Noties when the power is turned on.
2 ERST Error notication xxxxxx Noties when an error occurs.
2 LKUP Link up notication xx:xx:xx:xx:xx:xx
Noties the MAC address when the PJLink communication
becomes possible.
2 INPT
Input switch
completion notication
31 DVI-D
32 HDMI
33 DIGITAL LINK
34 SDI
35 SLOT-1 (input 1 of the Interface Board installed in the slot)
36 SLOT-2 (input 2 of the Interface Board installed in the slot)
37 SLOT-3 (input 3 of the Interface Board installed in the slot)
38 SLOT-4 (input 4 of the Interface Board installed in the slot)
2 SRCH Projector search
ACKN=xx:xx:xx:xx:xx:xx
The projector connected to the same network that can
communicate with PJLink will respond with its MAC address.
PJLink security authentication
The password used for PJLink is the same as that of the password set for web control.
When using the projector without security authentication, do not set a password for web control.
f For specications related to PJLink, visit the website of Japan Business Machine and Information System
Industries Association.
URL http://pjlink.jbmia.or.jp/english/
Using Art-Net function
Since the network function of the projector supports the Art-Net function, you can control the projector settings
with the DMX controller and application software using the Art-Net protocol.
Channel denition
The following table lists the channel denitions used for controlling the projector with the Art-Net function.
Channel settings can be switched using the [NETWORK] menu [Art-Net CHANNEL SETTING] (x page 180).
The control details assigned to each channel are listed in the following table.
f Channel assignment for [USER] is in factory default setting. Assignment can be changed.
Channel
Control details
[2] [USER] [1]
CHANNEL1 LIGHT OUTPUT LIGHT OUTPUT SHUTTER
CHANNEL2 INPUT SELECT INPUT SELECT INPUT SELECT
CHANNEL3 LENS POSITION LENS POSITION LENS FUNCTION SELECT
CHANNEL4 LENS H SHIFT LENS H SHIFT LENS CONTROL

Table of Contents