17/33
2.43. AUTO SETUP
Hexadecimal 02h 4Fh 53h 53h 3Ah *1 03h
Characte
O S S : *2
■Parameters (*1,*2)
ON1 ON2
Hexadecimal 30h 31h
Characte
01
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 53h 3Ah *1 03h
Characte
O S S : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × ○ ○ ○
■Note:
- This command is effevtive only when the Signal Search selects “ON2”. In other cases, ER401 is returned.
2.44. INPUT SEARCH
Hexadecimal 02h 4Fh 53h 52h 3Ah *1 03h
Characte
O S R : *2
■Parameters (*1,*2)
OFF ON2
Hexadecimal 30h 31h
Characte
01
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 52h 3Ah *1 03h
Characte
O S R : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × ○ ○ ○
2.45. BACKGROUND
Hexadecimal 02h 4Fh 42h 43h 3Ah *1 03h
Characte
O B C : *2
■Parameters (*1,*2)
BLUE BLACK USER
Hexadecimal 30h 31h 32h
Characte
0 1 2
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 42h 43h 3Ah *1 03h
Characte
O B C : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × ○ ○ ○
■Note:
- When the user regiterd Logo is not available, “BLUE” and “BLACK” are effective. In other cases, ER401 is returned.
2.46. DIRECT ON
Hexadecimal 02h 4Fh 50h 59h 3Ah *1 03h
Characte
O P Y : *2
■Parameters (*1,*2)
OFF ON
Hexadecimal 30h 31h
Characte
0 1
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 50h 59h 3Ah *1 03h
Characte
O P Y : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × ○ ○ ○