6/33
2.5. INPUT SELECT
Hexadecimal 02h 49h 49h 53h 3Ah *1 *3 *5 03h
Characte
I I S : *2 *4 *6
■Parameters (*1,*2,*3,*4,*5,*6)
COMPUTER1 COMPUTER2
Hexadecimal 52h 47h 31h 52h 47h 32h
Characte
R G 1 R G 2
VIDEO S-VIDEO
Hexadecimal 56h 49h 44h 53h 56h 44h
Characte
V I D S V D
SCART HDMI
Hexadecimal 53h 43h 54h 48h 44h 31h
Characte
S C T H D 1
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 49h 49h 53h 3Ah *1 *3 *5 03h
Characte
I I S : *2 *4 *6
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × ○ ○ ○
■Note:
- When the “Monitor out” is selected for COMPUTER2 with the terminal setting and then COMPUTER2 is selected, ER401
is returned.
2.6. FREEZE Key
Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h
Characte
O F Z : *2
■Parameters (*1,*2)
OFF ON
Hexadecimal 30h 31h
Characte
01
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h
Characte
O F Z : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × × ○ ○
2.7. FREEZE Key (TOGGLE)
Hexadecimal 02h 4Fh 46h 5Ah 03h
Characte
O F Z
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 46h 5Ah 03h
Characte
O F Z
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × × ○ ○
2.8. MENU Key
Hexadecimal 02h 4Fh 4Dh 4Eh 03h
Characte
O M N
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 4Dh 4Eh 03h
Characte
O M N
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × ○ ○ ○