2.88. Query STANDBY MODE
Hexadecimal 02h 51h 56h 58h 3Ah 53h 54h 4Dh 49h 30h 03h
Characte
Q V X : S T M I 0
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 53h 54h 4Dh 49h 33h 3Dh 2Bh
Characte
S T M I 3 = +
Hexadecimal *1 *3 *5 *7 *9 03h
Characte
*2 *4 *6 *8 *10
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
○ ○ ○ ○ ○ ○
■Parameters (*1,*2,*3,*4,*5,*6,*7,*8,*9,*10)
NORMAL
Hexadecimal 30h 30h 30h 30h 30h
Characte
0 0 0 0 0
ECO
Hexadecimal 30h 30h 30h 30h 33h
Characte
0 0 0 0 3
2.89. Query VOLUME
Hexadecimal 02h 51h 41h 56h 03h
Characte
Q A V
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 03h
Characte
*2 *4 *6
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
○ ○ × ○ ○ ○
■Parameters (*1,*2,*3,*4,*5,*6)
0 1 2
Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Characte
0 0 0 0 0 1 0 0 2
61 62 63
Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h
Characte
0 6 1 0 6 2 0 6 3
2.90. Query P IN P
Hexadecimal 02h 51h 50h 50h 03h
Characte
Q P P
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Characte
*2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
○ ○ × ○ ○ ○
■Parameters (*1,*2)
OFF SIDE BY SIDE P IN P
Hexadecimal 30h 31h 32h
Characte
01 2