EasyManua.ls Logo

Panasonic S-22MK1E5 - Page 33

Panasonic S-22MK1E5
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
LN
U1 U2 R1 R2
Stranded wire
Ring
pressure
terminal
Screw and
Special washer
Ring
pressure
terminal
Terminal plate
Ring pressure
terminal
Screw
Special
washer
Wire
Wire
Insulation tape
8mm
Insulation tape
Shield mesh
Shield mesh
Strip 10 mm
Fig. 4-5
Fig. 4-6
Fig. 4-7
Fig. 4-8
Fig. 4-9
Fig. 4-10
How to connect wiring to the terminal
For stranded wiring
(1) Cut the wire end with cutting pliers,
then strip the insulation to expose
the stranded wiring about 10 mm and
tightly twist the wire ends. (Fig. 4-5)
(2) Using a Phillips head screwdriver,
remove the terminal screw(s) on the
terminal plate.
(3) Using a ring connector fastener or
pliers, securely clamp each stripped
wire end with a ring pressure terminal.
(4) Place the ring pressure terminal,
and replace and tighten the removed
terminal screw using a screwdriver.
(Fig. 4-6)
Examples of shield wires
(1) Remove cable coat not to scratch braided shield. (Fig. 4-7)
(2) Unbraid the braided shield carefully and twist the
unbraided shield wires tightly together. Insulate the shield
wires by covering them with an insulation tube or wrapping
insulation tape around them. (Fig. 4-8)
(3) Remove coat of signal wire. (Fig. 4-9)
(4) Attach ring pressure terminals to the signal wires and the
shield wires insulated in Step (2). (Fig. 4-10)
Wiring samples
Functional ground screw (External Electronic
Expansion Valve Kit and Schedule Timer)
Use this screw when connecting the shield
for the Inter-unit control wiring to ground.
Protective ground screw (External Solenoid Valve Kit for 3WAY)
Protective ground screw (External Solenoid Valve Kit for 3WAY)
Power Supply
Inter-unit Control Wiring
Power Supply
Use this screw when connecting the shield
for the Inter-unit control wiring to ground.
Functional ground screw (External Electronic
Expansion Valve Kit and Schedule Timer)
Remote Control Wiring
Remote Control Wiring
D1 type L1 type
Inter-unit Control Wiring
PanaIndoor-337012Eng.indb32PanaIndoor-337012Eng.indb32 2012/03/2116:20:512012/03/2116:20:51

Table of Contents

Other manuals for Panasonic S-22MK1E5

Related product manuals