7. APPENDIX
■ When Using Wireless Remote Controller Instead of Wired Remote Controller
When the wireless remote controller is to be used, slide the switch (S011) on the indoor unit control PCB to the ON position.
● If this setting is not made, an alarm will occur. (The operation lamp on the display blinks.)
Setting status
ON: Wireless: main, Wired: sub
OFF: Wired: main, Wireless: sub (at shipment)
Slide
■ Troubleshooting
If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly,
contact your dealer or a service center.
●
Indoor unit
Symptom Cause
Noise
Sound like streaming water during
operation or after operation
●
Sound of refrigerant liquid flowing inside unit
●
Sound of drainage water through drain pipe
Cracking noise during operation or
when operation stops.
Cracking sound due to temperature changes of parts
Odor
Dischargedairissmelledduring
operation.
Indoor odor components, cigarette odor and cosmetic odor accumurated in
the air conditioner and its air is discharged.
Unit inside is dusty. Consult your dealer.
Dewdrop
Dewdropgetsaccumuratednearair
discharge during operation
Indoor moisture is cooled by cool wind and accumulated by dewdrop.
Fog
Fog occurs during operation in cooling
mode.
(Places where large amounts of oil mist
exist at restaurants.)
●
Cleaning is necessary because unit inside (heat exchanger) is dirty.
Consult your dealer as technical engineering is required.
●
Duringdefrostoperation
Fan is rotating for a while even though operation stops.
●
Fan rotating makes operation smoothly.
●
Fan may sometimes rotates because of drying heat exchanger due to
settings.
Wind-direction changes while operating.
Wind-direction setting cannot be made.
Wind-direction cannot be changed.
●
When air discharge temperature is low or during defrost operation,
horizontal wind flow is made automatically.
●
Flap position is occasionally set up individually.
●
When long-hour operation is made with fixed wind-direction, wind-direction
is controlled automatically and flap position is occasionally changed.
When wind-direction is changed, flap operates several
times and stops at designated position.
When wind-direction is changed, flap operates after searching for standard
position.
Dust Dustaccumulationinsideindoorunitisdischarged.
●
Outdoor unit
Symptom Cause
No operation
When power is turned ON instantly.
Operation is not acticated for the first approx. 3 minutes because compressor
protection circuit is activated.
When operation is stopped and
resumed immediately.
Noise Noise often occurs in heating mode.
Duringdefrostoperation
Steam Steam often occurs in heating mode.
When stopped by remote controller, outdoor unit fan is
sometimes operating for a while even though outdoor
compressor is stopped.
Fan rotating makes operation smoothly.