Item Operational
Condition and Key
Function
Details Display TO Exit Mode
Measurement of CD
laser current electricity
While the player is
stopped and no disc is
inserted, press and
hold down the
button on the player
and the number button
“3” onthe remote
controller unit.
Measurement of CD laser current
electricity
Measures CD laser current electricity
and displays the result together with
the initialization value stored in
EEPROM. After measurement, CD
laser is lit tillthe power is turned off (or
goes off when the primary power is
turned off).
LDC
*1
_032
*2
_032
*3
*1
: CD laser current electricity
measurement mode
*2
: Current electricity
initializationvalue stored in
EEPROM
*3
: Present value of current
electricity
Values are shown in the decimal
digit. The above example indicates
the current electricity initialization
value is 28mA and its presentvalue
is 26mA when laser is turned on.
Automatically exits
the mode after five
seconds.
User initialization While the player is
stopped and no disc is
inserted, press and
hold down the
button on the player
and the number button
on the remote
controller unit.
User initialization
The user setting recovers the factory
setting.
“INITIALIZE” -
Region display While the player is
stopped and no disc is
inserted, press and
hold down the
button on the player
and the number
button, “6” onthe
remote controller unit.
Region display [srrrxxyzzzz]
s : Panecon model type
rrr : Panecon release number
x : Syscon generation (45)
y: Syscon model type
zzz: Syscon release number
Automatically exits
the mode after five
seconds.
Firmware version
display
While the player is
stopped and no disc is
inserted, press and
hold down the
button on the player
and the number
button, “7” on
theremote controller
unit.
Firmware version display rrr
*1
_xx
*2
y
*3
zzz
*4
*1
: Panel computer release number
*2
: System computer generation
*3
: Systemcomputer model type
*4
: System computer release
number
Automatically exits
the mode after five
seconds.
Region and firmware
display
While the player is
stopped and no disc is
inserted, press and
hold down the
button on the player
and the number
button, “8” on
theremote controller
unit.
Region and firmware version display _r
*1
__xx
*2
y
*3
zzz
*4
*1
: Region number
*2
: System computer generation
*3
: Systemcomputer model type
*4
: System computer release
number
Automatically exits
the mode after five
seconds.
Laser use time While the player is
stopped and no disc is
inserted, press and
hold down the
button on the player
and the
button
on the remote
controller unit.
Laser usage time
Measures each for DVD and CD
respectively.
T1_1234_5678
The numbers in the left show
usage time for DVD laser and
those in the right for CD laser. The
four-digit number is shown by the
ten hours in the decimal digit. The
number after 0000 is 9999.
Automatically exits
the mode after five
seconds.
Reset laser use time While the usage time 1
is displayed, press and
hold down the
button on the player
and the
button
on the remote
controller unit.
Laser usage time reset
Resets both for DVD and CD at once.
T1_0000_0000 Automatically exits
the mode after five
seconds.
Spindle use time While the player is
stopped and no disc is
inserted, press and
hold down the
button on the player
and the
button
on the remote
controller unit.
Spindle motor usage time T2_12345
The four-digit number is shown by
the ten hours in the decimal digit.
The number after 00000 is 99999.
Automatically exits
the mode after five
seconds.
27
SA-VK81DEE