Self Check
Display Indication
1. Self check is used to automatically check the bus line controlled circuit of the LCD display.
2. To get into the Self check mode, press the volume down button on the customer controls at the right side of the set, at the
same time pressing the OFF TIMER button on the remote control, and the screen will show.
Method A Self-Check only ( A shipment setup is not carried out )
Select ID mode by UP/Down button on the remote control at the front page of CAT mode and then press the Mute button
on the remote control more then 3 seconds.
Method B Self-Check + Shipment setup
Press and hold the volume down button on the right side of the unit and press the OFF-TIMER button on the remote
control.
If the IIC ports have been checked and found to be incorret, or not located then “- -” will appear in place “OK”
“0A” in the lie of the “PTCP” means the number of blinks of the Power LED is 10. (Reference_Power LED blinking timing
chart)
“H09” in the line of the “PTCP” is the error code
To exit the CAT mode switch off the main power.
Note:
The line of the “PTCP” display when you get into the Self check mode for first time only after the Power LED blinks.
A H90MEM OK
H51RTC OK
H62TEMP OK
H38FRC OK
ADC Adjust OK
ID
IIC1 IIC2