PAGE 16 EVO/DGP System Programming
(see “Optional External Temperature Sensor” on page 9). If set as a
temperature input, Grafica represents it as the outside temperature
on the System Status screen next to the word “OUT”.
Option [7] OFF = Temperature sensor input (default)
Option [7] ON = Zone input
Keypad Tamper
SECTION [002]: OPTION [8]
When the keypad tamper option is enabled and the keypad's anti-
tamper switch (optional) is triggered, the keypad will send a Tamper
report to the control panel via the combus.
Option [8] OFF = Grafica’s tamper option is disabled (default)
Option [8] ON = Grafica’s tamper option is enabled
Beep on Trouble
SECTION [003]: OPTIONS [1] TO [4]
Potential troubles have been sorted into groups. With these options
enabled, the keypad will emit an intermittent beep tone whenever a
trouble condition occurs from one of the trouble groups. The
intermittent beep will remain activated until the user enters Grafica’s
Trouble Display or if the trouble is resolved. For a list of troubles, see
the appropriate control panel’s Reference and Installation Manual.
The intermittent beep will be re-initialized whenever the trouble
condition reoccurs.
System and Clock Trouble Beep
SECTION [003]: OPTION [1]
O
ption [1] OFF = Beep disabled (default)
Option [1] ON = Beep on: System Troubles and Clock Loss
Communicator Trouble Beep
SECTION [003]: OPTION [2]
Option [2] OFF = Beep disabled
Option [2] ON = Beep on: Communicator Troubles (default)
Module and Combus Trouble Beep
SECTION [003]: OPTION [3]
Option [3] OFF = Beep disabled (default)
Option [3] ON = Beep on: Module and Combus Troubles