Spectra 1727 11
night, doors and windows can be armed without arming
other zones like motion detectors.
When you have correctly Stay Armed the system, the
Exit Delay will start (see section 4.1). The ARM Light will
flash when the Exit Delay elapses. Also, you can Stay
Arm by using One-Touch Arming (see section 4.7).
4.5 FORCE ARMING
Force Arming allows you to arm the system without
waiting for all zones in the system to close. Certain
zones are programmed as Bypass Enabled Zones, which
are bypassed when Force Arming. When Force Arming,
a Bypass Enabled Zone is considered deactivated until it
closes. Once it closes, the zone is armed.
Force Arming is commonly used when a motion detector
is protecting the area occupied by a keypad. For
example, when you are in the path of a Bypass Enabled
motion detector, use Force Arming to arm the system.
How Do I Stay Arm?
1) Close all zones except Stay Zones.
2) Press the [STAY] button
3) Enter your [ACCESS CODE]

Other manuals for Paradox SPECTRA 1727