[4] OFF / [5] ON: Audible Pulsed Alarm
When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report
code (see page 33) and provides a pulsed output (see Figure 5-2 on page 20) for any bells or sirens connected to the
control panel’s bell output.
[4] ON / [5] OFF: Silent Alarm
When the conditions for an alarm are met, the control panel can transmit the appropriate Zone Alarm report code (see
page 33) and will not activate the control panel’s bell output. The appropriate
ARM or STATUS LED on the keypads will
flash to indicate an alarm and the user will still have to disarm the system.
[4] ON / [5] ON: Report Only
When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report
code (see page 33). The system will not have to be disarmed.
5.8.5 INTELLIZONE
Sections [001] to [015]: Zones 1 to 15
Option
[6]
OFF = Intellizone Disabled (default)
Option
[6]
ON = Intellizone Enabled for Selected Zone
This feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the panel does not
immediately generate an alarm. First it triggers the Intellizone Delay Timer. To program the Intellizone Delay Timer, key
in the desired 3-digit value (010 to 255 seconds, Default = 48 seconds) into section [084]. If any of the following
conditions occur during this period, the panel will generate an alarm:
During the Intellizone Delay, a second zone has caused an alarm.
During the Intellizone Delay, the zone in alarm has restored (closed) and re-occurred (opened).
The zone in alarm remains open for the entire Intellizone Delay.
5.8.6 DELAY BEFORE ALARM REPORT CODE TRANSMISSION
Sections [001] to [015]: Zones 1 to 15
Option
[7]
OFF = Delay Alarm Transmission Disabled (default)
Option
[7]
ON = Delay Alarm Transmission Enabled for Selected Zone
When an alarm condition occurs on a zone with this option enabled, the control panel enables the bell/siren output, but
does not report the alarm to the central station until the end of the Alarm Before Transmission Delay. To program the
Alarm Transmission Delay, key in the desired 3-digit delay value (000 = Disabled, 001 to 255 seconds) into section
[080]. During this period, disarming the system disables the bell/siren output and cancels the report code transmission.
This feature is commonly used with Entry Delay zones to reduce false alarms created by new users who may not
disarm the system in time.
5.8.7 FORCE ZONES
Sections [001] to [015]: Zones 1 to 15
Option
[8]
OFF = Force Zone Disabled (default)
Option
[8]
ON = Selected Zone is Force Enabled
Any open Force Zones at the time of arming will be considered deactivated by the control panel (see page 49). If
during this period a deactivated zone is closed, the control panel will revert that zone to active status. Consequently,
the control panel will generate an alarm if the zone is breached.
Do not program a Fire Zone with the Force option, as the control panel will never bypass Fire Zones
when Force Arming.
5.8.8 KEYSWITCH OPTIONS
Sections [001] to [004]: Option [1] and [2]
When an on-board zone is programmed as a Keyswitch Zone (see section 5.6.1 on page 19), the control panel will
ignore any other Zone Option. The keyswitch can be programmed as a Maintained or Momentary Keyswitch and to
Regular or Stay Arm (see section 13.4 on page 48). A Maintained Keyswitch will arm the system when it is set to the
ON position and will disarm when set to the OFF position. To arm with a Momentary Keyswitch, set the keyswitch to the
ON position then turn it back to the OFF position. Repeating this sequence will disarm the system. Program the
keyswitch with the following:
Option [1] OFF = Maintained (default) Option [2] OFF = Regular Arming (default)
Option [1] ON = Momentary Option [2] ON = Stay Arming

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra 1759EX V1.0 and is the answer not in the manual?

Paradox Spectra 1759EX V1.0 Specifications

General IconGeneral
BrandParadox
ModelSpectra 1759EX V1.0
CategoryControl Unit
LanguageEnglish

Related product manuals