4
6
REFERENCE & INSTALLATION MANUAL
instructions on the ADP-1 adapter. When the computer has dialed, press [ENTER] followed by the Installer Code, then press the
[
FORCE] key to manually answer the WinLoad software from the control panel.
12.7 AUTO EVENT BUFFER TRANSMISSION
Section [136]: Dialer Options
Option
[2]
OFF = Auto Event Buffer Transmission Disabled (default)
Option
[2]
ON = Auto Event Buffer Transmission Enabled
When the event buffer reaches 50% capacity, the control panel will make two attempts to establish communication with a PC
using the WinLoad software by calling the PC Telephone Number programmed in section [150]. The WinLoad software must be
in Wait to Dial mode. When the system establishes communication, it will upload the contents of the event buffer to the WinLoad
software. If communication is interrupted before completing transmission or if after two attempts communication is not
established, the system will wait until the Event Buffer attains another 50% capacity before attempting to re-communicate with the
central station. When the Event Buffer is full, each subsequent new event will erase the oldest event in the buffer.
12.8 CALL BACK WINLOAD
Section [136]: Dialer Options
Option
[1]
OFF = Call Bac k WinLo ad Disa ble d (defa ul t)
Option
[1]
ON = Call Bac k WinLo ad En ab led
For additional security, when a PC using the WinLoad software attempts to communicate with the control panel, the control panel
can hang up and call the PC back in order to re-verify identification codes and re-establish communication. When the control
panel hangs up, the WinLoad software automatically goes into Wait for Call mode, ready to answer when the control panel calls
back. Please note that the PC Telephone Number must be programmed in section [150] in order to use the Call Back feature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra 1759EX V1.0 and is the answer not in the manual?

Paradox Spectra 1759EX V1.0 Specifications

General IconGeneral
BrandParadox
ModelSpectra 1759EX V1.0
CategoryControl Unit
LanguageEnglish

Related product manuals