Keypad Description
Master Reset - Clears time and program. Display will show “MEM CLR.” The reset switch is
accessed by inserting a pointed object, such as a paper clip, into the reset
hole to the right of the keypad.
PROGRAM - This key allows the user to add, delete or change parameters (events, time,
holidays, etc.).
When pressed from the RUN mode, the programming menu is displayed
starting with the TIME menu header.
When pressed from a menu header, the control will advance to the next menu
header.
When pressed from a programming step, the control returns to that menu
header.
When pressed during review, the control will go to the appropriate program-
ming display.
REVIEW - This key allows the user to review all the programmed steps using displays
condensed to show as much information as possible on one display. The user
will not be able to change the program in the Review mode.
When pressed from the RUN mode or any programming step within a menu
header, the control will return to the TIME menu header.
12