Gemini GT6 Hardware Installation Guide
Digital Outputs
Command Description Options:
Output Definition and Sense configure up to 7 outputs
Analog Monitors
Command Description Options:
DMONAV analog monitor A variable unused/turn off output
drive temperature
velocity setpoint
acceleration setpoint
phase A commanded current
phase A actual current
phase B commanded current
phase B actual current
phase A commanded voltage
phase B commanded voltage
DMONAS analog monitor A scaling
1
you enter a percentage
1
DMONBV analog monitor B variable same choices as DMONAV
DMONBS analog monitor B scaling
1
you enter a percentage
1
1
Monitor output is scalable from -2000% to +2000%, but is limited to ±10V peak to peak.
Communications Settings
The communication settings configure the drive for RS-232/485 communications.
RS-232/485
Command Description Options:
ERRLVL error level you enter a number
ECHO echo enable can be turned on or off
Motor Control Settings
Motor control settings are divided into two groups: motor matching, and damping .
Motor Matching
Motor matching is used to match the drive to your specific motor. A procedure for
performing motor matching is presented at the end of this chapter. Relevant
commands are:
Command Description Options:
DWAVEF % 3rd harmonic current you enter a number
waveform component
DPHBAL phase B balance you enter a percentage
DPHOFA phase A current offset you enter a percentage
DPHOFB phase B current offset you enter a percentage