EasyManuals Logo

Parker GT Series User Manual

Parker GT Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
26
Gemini GT Hardware Installation Guide
Digital Outputs
Command Description Options:
OUTLVL output sense active high or active low
(outputs 2, 3 and 4 can be set independently)
Analog Monitors
Command Description Options:
DMONAV analog monitor A variable unused/turn off variable
drive temperature
velocity setpoint
acceleration setpoint
phase A commanded current
phase A actual current
phase B commanded current
phase B actual current
phase A commanded voltage
phase B commanded voltage
DMONAS analog monitor A scaling
1
you enter a percentage
1
DMONBV analog monitor B variable same choices as DMONAV
DMONBS analog monitor B scaling
1
you enter a percentage
1
1
Monitor output is scalable from -2000% to +2000%, but is limited to ±10V peak to peak.
Communications Settings
The communication settings configure the drive for RS-232/485 communications.
RS-232/485
Command Description Options:
ERRLVL error level you enter a number
ECHO echo enable can be turned on or off
E listening can be turned on or off
Motor Control Settings
Motor control settings are divided into two groups: motor matching, and damping
settings.
Motor Matching
Motor matching is used to match the drive to your specific motor. A procedure for
performing motor matching is presented at the end of this chapter. Relevant
commands are:
Command Description Options:
DWAVEF % 3rd harmonic current you enter a number
waveform component
DPHBAL phase B balance you enter a percentage
DPHOFA phase A current offset you enter a percentage
DPHOFB phase B current offset you enter a percentage
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker GT Series and is the answer not in the manual?

Parker GT Series Specifications

General IconGeneral
Horsepower0.5 to 15 HP
FeedbackTachometer
Protection RatingIP20
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating ModesSpeed Control, Torque Control

Related product manuals