192-510014 N04 March 2010 39
6.2 Electrical limit switches
LCB040
12 1
6
4,5
4,5
7
5
10
40
51
60
2
6
LCB060
1
2
5
2
6
3
5
69
5,5
2
5
6
4,5
5
20
40
80
Connection diagram LCB040 and LCB060
1: PNP normally closed contact
2 -3: Load
A
2
3
1
br
sw
bl
bn
bk
bu
Technical data: limit switches LCB040 and LCB060 Electrical characteristics
Switching distance 2 mm / 4 mm ± 10 % Rated Voltage 24 VDC
Switch hysteresis > 1 % ...< 15 % Voltage range 10...35 VDC
Repeatability 0.01 mm Supply current < 15 mA
Temperature drift < 10 % Maximum load current 300 mA
Ambient temperature -25 °C - +70 °C Residual voltage < 2.5 VDC
Protection class IP67 Switching frequency 2 kHz
Cable Length 6 m Connecting cables 3 x 0.25 mm
2