Time Zone card
(Used to replace the door contact function with the time zone function)
The time zone function allows two different sets of colour zones to be set up and then a
time clock is used to switch between these two sets at programmed times. (See Wiring –
Time Clock). For example, a site may allow full access to all colour zones during the day
and then switch to only RED card holders at night.
To enable the time zone function, swipe this card through the reader. The control unit
beeps and all the LEDs go out and come back on. To return the ‘Contact’ input to its
default function, just swipe the time zone card through the reader again.
The time clock can now be programmed and coloured zones set up. (To enable/disable
coloured zones see - GREEN, AMBER and RED Zone cards).
Set the clock to short together the Contact and Black terminals. Configure the colour
zones with their zone cords and observe the LEDs as confirmation. Remove the short
from the clock output and set up any changes required in the ‘Default’ state. The two
colour zone sets will then be enabled/disabled depending on the state of the time clock
connection.
Bar All Users card
This card should be used if the majority of users on the system need to be barred. The
card should be swiped through the reader once. After 2 seconds the control unit will beep
twice and the GREEN, AMBER and RED LEDs will go out and come back on. All users will
now be barred. To re-enrol individual users back on the system see – Enrolment card.
Relay Toggle card
This card should be used if the output from the Switch2 control unit needs to be a toggle
output. Toggle means that instead of the relay opening for a set time and then closing,
the relay will stay open until a user card is swiped through the reader to close it again.
By default the control unit is set up in timed mode.
To set the system in toggle mode the relay toggle card needs to be swiped through the
reader. The control unit will beep twice and the GREEN and AMBER LEDs will go out. The
RED and arrow LED lit. (Default condition)
If a user card is swiped through the reader, the relay output will change state and the
GREEN LED will come on by itself. If the card is swiped through again the relay state will
change back, the RED LED comes on alone - and so on.
To return to the standard relay timed mode, swipe the Toggle card again. The Switch2
control unit will beep twice and all the LEDs will now be on.
Default Settings
User cards .............................. all cards encoded will be valid
Zone LED status ............................. all LEDs/zones will be on
Squeak setting .....................................................activated
Door open time....................................................7 seconds
Remote button ......................Switch relay for door open time
Time zones ........................................................... Inactive
Relay toggle..........................................................Disabled
Chapter 5 Operation 24

Other manuals for Paxton Switch2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paxton Switch2 and is the answer not in the manual?

Paxton Switch2 Specifications

General IconGeneral
TypeProximity access card
MaterialPlastic
Product colorBlack, Green
Wireless connectionYes
Operating temperature (T-T)0 - 55 °C
Weight and Dimensions IconWeight and Dimensions
Depth49 mm
Width28 mm
Height11 mm

Related product manuals