TAMPER EVIDENT NECK BANDING AND SHRINKSLEEVE LABELING MACHINERY
8 Sheehan Avenue, South Norwalk, CT 06854 USA 203-853-1516 F 203-854-0834 www.pdc-corp.com
There are five (5) steam control valves on each side of the steam tunnel for a total
of ten (10) steam control valves on the entire tunnel.
Each of the steam control valves has a flow control scale as indicated by the valve
indicators. An operator can select a setting of “0” (fully closed), “1/4”, “1/2” ,
“3/4”, or “OPEN” (fully open).
Be sure to reseal each door panel with the top end of the T wrench (or a
screwdriver) when finished (turn screwdriver, or T wrench, a half turn to secure
door).