Max. Efficiency
Euro Efficiency
MPPT Accuracy
Efficiency
97.2%
96.7%
> 99.5%
97.1%
96.6%
> 99.5%
Topology
Consumption at Night
Consumption at Standby
Operating Temperature Range
Cooling Method
Ambient Humidity
Altitude
Noise
Overvoltage Rating
Ingress Protection
Mounting
Dimensions (H x W x D) [mm]
Net Weight
Warranty [Year]
General Data
Transformerless
< 0.2 W
6 W
From -25 °C to + 60 °C (45 °C to 60 °C with derating)
Natural Convection
From 0% to 100% Non-condensing
Up to 2000 m (without derating)
< 15 dBA
II (DC input) III (AC output)
IP65 (Indoor & Outdoor Installation)
Rear Panel
315 x 260 x 120
5.6 kg
5 (standard) / 10 (optional)
AC Connection
DC Connection
LCD
LED Display
Display Language
Datalogger & Communication
Interface
Plug-in connector
MC4 / H4
LCD (16 x 2 characters, backlight)
LED (3 lights)
Italian / English / Spanish
RS-232 / Wi-Fi (opcional)
Certicates
For a complete list of certicates visit www.peimar.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Peimar Mirus Series and is the answer not in the manual?

Peimar Mirus Series Specifications

General IconGeneral
BrandPeimar
ModelMirus Series
CategoryInverter
LanguageEnglish

Related product manuals