Example Error Screens
Detected Error
DETECTED ERROR=
E2 RESET UNIT
1. Go through Master Programming to program the unit.
No Message #1
DETECTED ERROR=
NO MESSAGE #1
1. Make sure all communication cables are connected.
2. If "No Message #1" ensure it is the lead unit.
3. Ensure #1 is configured for the correct system type.
No Message #3
DETECTED ERROR=
NO MESSAGE #3
1. Make sure all communication cables are connected.
2. If "No Message #3" ensure it is unit #3.
3. Ensure #3 is configured for the correct system type.
Program Mismatch
DETECTED ERROR=
PROGRAM MISMATCH
1. Ensure the units on the network are not configured the
same as #1/the Lead unit.
Exceed Unit Size
DETECTED ERROR=
EXCEED UNIT SIZE
1. There are more units on the system than the Lead is
programmed for.
Matching Address
DETECTED ERROR=
MATCHING ADDRESS
1. The unit is programmed the same # as another unit.
NOTE: The rest of the system will still function without this
unit.
TROUBLESHOOTING continued GENERAL SERVICE HINTS FOR METER
CONTROL
Problem: Softener delivers hard water
Reason: Reserve capacity has been exceeded.
Correction: Check salt dosage requirements and review
programmed unit capacity, capacity safety factor, and feed
water hardness settings.
Reason: Meter is not measuring flow.
Correction: Check meter with meter checker.
FLECK 7000 NXT Service Manual • 21