TIME OF DAY PROGRAMMING MODE
FLOW CHART
Setting the Time of Day
NOTE: Set Time of Day on any unit and the rest of the units in
the system will update the Time of Day automatically.
1. Press and hold the Up button for 2 seconds.
The "Time" value is displayed. Press the Up or Down
buttons to adjust as desired.
2. Press the Extra Cycle button to advance to the "Year" field.
Press the Up or Down buttons to adjust as desired.
3. Press the Extra Cycle button to advance to the "Month"
field. Press the Up or Down buttons to adjust as desired.
4. Press the Extra Cycle button to advance to the "Calendar
Day" field. Press the Up or Down buttons to adjust as
desired.
5. Press the Extra Cycle button to return to the normal display
screen.
NOTE: Press and hold the Left button to exit without saving.
END
Example:
12 or 24 hour formats available
11:00AM
TIME
Example:
Set current year
2018
YEAR
Example:
Set current month
JAN
MONTH
Example:
Set current day
22
CALENDAR DAY
Settings Review x x x x x x x x x x
Language x x x x x x x x x x
Assistance Name 1, 2 x x x x x x x x x x
Assistance Phone x x x x x x x x x x
Regen Type x x x x x x x x x x
Valve x x x x x x x x x x
Regen Flow x x x x x x x x x x
Units x x x x x x x x x x
Remote Regeneration x x x x x x x x x x
Auxilliary 1,2 x x x x x x x x x x
Lock Window 1,2 x x x x x x x x x x
Meter Type x x x x x x x x
Continuous Flow Detect x x x x x x x x
Save as Non Factory x x x x x x x x x x
Lock Settings x x x x x x x x x x
Day Override/Time Driven x x x x x x x x x
Capacity x x x x x x x x 0-9,999,999 Grains 0-9,999,999 Grams, 0-560,287 Lx°DH, 0-1,000,000 Lx°FTH, 0-701,557 Lx°EH
Hardness x x x x x x x x 0-199 GPG 0-19,999 mg/L, 0-1,402 °EH, 0-199.9 °FTH, 0-112 °DH
International Hardness Units
x x x x x x x x
Reserve x x
Number of Tanks (Max) 1 1 1 1 8 8 2 2 8 8
Push Settings x x x x x x
Trip Point #1-7 GPM x 0-1,999 GPM 0-7,569 LPM
Weekly Reserve, Variable Reserve, Fixed %, Fixed Volume
2, 3, 4, 5, 6, 7, 8
Alarm Based,
Cycle Based,
Time Based,
Paddle (0.75", 1", 1.5", 2", 3")
Turbine (0.75", 1.25", 1.5")
Generic
Off, Delayed, Enter Code, Time Based
Off-99 Days
SU, MO, TU, WE, TH, FR, SA
Series Alternating Alternating Alternating Demand Recall
Francais
Deutsch
Italiano
Espanol
Nederlands
Day of the Week
Softener/Filter Metered Immediate
Softener/Filter Metered Delayed
2750
2815
2850
2900
3150
3900
Interlock
NXT2 Programming Parameters and Ranges
System Type 4 5 6 7 8 9 14
Programming Parameter Ranges
Regen Type Time Clock
Day of the
Week
Metered
Immediate
Softener/Filter
Metered Delayed
12 • Pentair Fleck NXT2 Timer Pentair Fleck NXT2 Timer • 13