ELECTRONIC SXT
25
2 - PROGRAMMING 5000 FILTER
E
N
G
L
I
S
H
Set the clock on 12:01, and exit time of day programmation
mode by pressing . Then press simultaneously on the
and buttons for 5 seconds.
1. Display unit (DF)
- Gallon [GAL]
- Liter [Ltr]
2. Valve type (VT)
- 5000 Filter [Othr]
3. Regeneration type (CT)
- Time clock [tc]
- Weekly time clock [ d AY ]
- Metered delayed [Fd]
- Metered immediate [FI]
4. Valve type (NT)
- 5000, 5600, 2510, 2750, 2850, 2910
5. Regeneration day override (DO)
i.e. : regeneration every 7x days
6. Regeneration time (RT)
i.e.: Regeneration at 2:00 AM
7. Regeneration cycle time setting
5000
Not used, do not put OFF
Backwash
Rapid rinse
Cycle cancelled
8. Define the regeneration days of week
Viewed in time clock week mode
8.1 Regeneration on Monday
8.2 No regeneration on Tuesday
8.3 No regeneration on Wednesday
8.4 No regeneration on Thursday
8.5 Regeneration on Friday
8.6 No regeneration on Saturday
8.7 Regeneration on Sunday
8.8 Day of the week to be indexed
i.e.: Thursday
Return in service mode
1. Press once the button
to go from one display
mode to another.
2. Set parameters values by
using the and
buttons.
3. Depending on the
programmation, some
displays will not appear
and some will not be
variable.