74 KENR9126
Troubleshooting Section
Results:
OK STOP.
i02655551
CID 0001 FMI 02
Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following condition:
Data from the electronic unit injector for the No. 1
cylinder is out of limits.
Diagnostic code 0168-01 is not active.
Diagnosti
c codes 0001-05 and 0001-06 are not
active.
No 0041 di
agnostic codes are active.
No 0262 diagnostic codes are active.
Diagnostic code 0190-08 is not active.
No 0110 d
iagnostic codes are active.
System Response:
If equipped, the warning light will come on. An active
diagnostic code will be generated. The ECM will log
the dia
gnostic code.
Possible Performance Effect:
The engine will be derated while this diagnostic code
is active.
Troubleshooting:
Perf
orm the following diagnostic procedure: “Injector
Data Incorrect - Test”
Resu
lts:
OK STOP.
i04053149
CID 0001 FMI 05
Conditions Which Gen erate This Code:
This diagnostic code is designed to indicate an open
circuit (low current). The open circuit can be in either
the solenoid
or the wiring for the electronic unit
injector for No. 1 cylinder.
The Electro
nic Control Module (ECM) detects the
following condition:
Alowcurre
nt condition (open circuit) for each of
ve consecutive attempts to operate
Battery vo
ltage is higher than 9 VDC for 2 seconds.
System Response:
If equipped, the warning light will come on. The ECM
will log the diagnostic code.
Possible Pe rformance Effect:
The engi
ne will have low power and/or rough running.
Troubleshooting:
When an injector cutout test is performed, a faulty
electronic unit injector will indicate a low reading in
compar
ison with the other electronic unit injectors.
An electrical fault can prevent the electronic unit
injec
tor from operating. An open circuit in the wiring
that is unique to the electronic unit injector will prevent
that individual electronic unit injector from operating.
An ope
n circuit in common wiring within the ECM can
prevent the three electronic unit injectors that share
that common wiring from operating.
The ECM will continue to attempt to operate the
electronic unit injector after the diagnostic code has
been
logged but an open circuit will prevent the
operation of the electronic unit injector.
Per
form the following diagnostic procedure: “Injector
Solenoid Circuit - Test”
Res
ults:
OK STOP.