92 KENR9126
Troubleshooting Section
Troubleshooting:
Perform the following diagnostic procedure:
“Transmission Oil Temperature Sensor Open or Short
Circuit - Test
Results:
OK STOP.
i04015789
CID 0190 FMI 08
Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following conditions:
The ECM detected an intermittent loss of signal
or a complete loss of signal from the primary
speed/ti
ming sensor for 2 seconds.
The engine has been running for more than 3
seconds
.
System Response:
If equipped, the diagnostic light will come on and the
diagnostic code will be logged.
The ECM will use the signal from the secondary
speed/timing sensor.
Possible Performance Effect:
The en
gine will be derated. If the signal from the
secondary speed/timing sensor is also lost, the
engine will shut down.
Troubleshooting:
This
diagnostic code will detect a loss of signal from
the primary speed/timing sensor.
Perf
orm the following diagnostic procedure: “Engine
Speed/Timing Sensor Circuit - Test”
Res
ults:
OK STOP.
i04015824
CID 0253 FMI 02
Conditions Which Gen erate This Code:
The Electronic Control Module (ECM) detects
incorrect engine software.
System Response:
If equipped
, the diagnostic light will come on.
This diagnostic code is not logged.
Factory passwords are required to clear this
diagnostic code.
Possible Pe rformance Effect:
The engin
ewillnotstart.
Troubleshooting:
The ash le in the ECM is from the wrong engine
family.
Use the electronic service tool to install the correct
ash le into the ECM. Refer to the Troubleshooting,
“Flash P
rogramming”.
Perform the following diagnostic procedure: “None”
Results:
OK ST
OP.
i04021000
CID 02
61 FMI 11
Conditions Which Gen erate This Code:
The E
lectronic Control Module (ECM) detects the
following conditions:
The
outputs from the primary speed/timing sensor
and the secondary speed/timing sensor differ by
more than 8 degrees on the crankshaft.
The engine has been running for more than 5
seconds.
Diagnostic code 0190-08 is not active.
No
0041 diagnostic codes are active.

Table of Contents