KENR9126 93
Troubleshooting Section
System Response:
If equipped, the diagnostic light will come on. This
code will not be logged.
Possible Performance Effect:
The pressure
in the fuel rail may be unstable and the
engine may not run smoothly.
Troublesho
oting:
Check the timing of the fuel rail pump. Refer to
Disassembl
y and Assembly, “Fuel Injection Pump
-Install.
Results:
OK STOP.
i03451885
CID 0262 FMI 03
Conditi
ons Which G enerate This Code:
The Electronic Control Module (ECM) detects the
followi
ng conditions:
The 5 Volt supply is greater than 5.16 Volts DC for
more th
an one second.
The ECM has been powered for at least three
second
s.
Diagnostic code 0168-01 is not active.
System Response:
The EC
M sets all of the pressure sensors and
temperature sensors to the default values.
Poss
ible P er formance Effect:
The engine will be derated.
Troubleshooting:
Thi
s diagnostic code will detect an excessively high
voltage in the 5 Volt supply circuit.
Per
form the following diagnostic procedure: “5 Volt
Sensor Supply Circuit - Test”
Re
sults:
OK STOP.
i03451888
CID 0262 FMI 04
Conditions Which Gen erate This Code:
The Engine Control Module (ECM) detects the
following conditions:
The 5 Volt supply is less than 4.84 Volts DC for
more than one second.
The ECM has been powered for at least three
seconds.
Diagnostic code 0168-01 is not active.
System Res
ponse:
The ECM sets all of the pressure sensors and
temperat
ure sensors to the default values.
Possible Pe rformance Effect:
Theenginewillbederated.
Trouble
shooting:
This diagnostic code will detect an excessively low
voltage
in the 5 Volt supply circuit.
Perform the following diagnostic procedure: “5 Volt
Sensor
Supply Circuit - Test”
Results:
OK STOP.
i04015832
CID 0268 FMI 02
Conditions Which Gen erate This Code:
The Electronic Control Module (ECM) detects one or
more of the following conditions:
One or more of the following conguration
parameters are not programmed. The effect on the
ECM
depends on the parameter.
FLS or FTS
Trim codes for the injectors
En
gine serial number
Equipment identication