Adjustment
12
1.05.07 Feeding stroke difference
Requirement
With the maximum stitch length set, when the balance wheel is turned the feeding stro-
kes of the needle and the bottom feed dog should be the same.
● With connecting rod 1 (nut 2) increase ("+") or reduce (-) the needle feed stroke in
accordance with the requirement.
1
2
Fig. 1 - 07