PFT G 5 SUPER Operating Manual Issued 11.2008
Knauf PFT GmbH & Co.KG
30
Insert cleaning shaft and mixing tube cleaner with scrapers facing down.
Shut motor flange and lock snaps, connect 5-pin plug on CADDY.
Press green button (on), run for approx. 5 - 10 secs. until mixing tube is
clean.
Press red button (off), remove cleaner.
Fit in clean mixing shaft.
Shut motor flange and lock snaps.
Empty the material hopper if the machine is unlikely to be used for some
days. Open the hopper-cleaning flap and remove the star wheel i
necessary.
WARNING!
Before opening the hopper-cleaning flap, switch off electricity mains
and all power supply