PFT G 5 SUPER Operating Manual Issued 11.2008
Knauf PFT GmbH & Co.KG
32
Release tie rods, remove pump. Press the rotor out of the stator and clean
it thoroughly. Clean pressure flange or after mixer (ROTOMIX o
ROTOQUIRL).Clean mixing zone and mixing shaft with water and a trowel.
Assemble the pump fully and prepare it for operation again.
Measures for Water Supply Failure
Use suction inlet (Item No. 00 00 69 06) to supply the machine with clean water.
Measures for Suzero Temperatures
Ater cleaning machne:
Cut of water supply.
Remove mixing shaft.
Open water outlet valve (1), release water pressure in hose.
Turn off water connection, remove water hose, empty it.
Open outlet taps on water manifold.
Remove air hose from spraying gun and fit it to water inlet.
Switch on main switch and press green button (on).