PFT G 5 SUPER Operating Manual Issued 11.2008
Knauf PFT GmbH & Co.KG
34
Transport
First disconnect mains, then all other power connections.
Remove water connections.
The PFT G 5 SUPER consists of three modules (CADDY, mixing tube and
material hopper) that can be transported individually.
Disassemble mixing tube, if necessary
.
WARNING!
Depressurize all hoses before disconnecting them.
Watch the readings on the mortar pressure gauge.
Maintenance
Clean compressor filter after every operation, if necessary, by knocking out
dirt. Replace filter if it is heavily soiled.
NOTE!
The coarse side of the filter should be on the inside!
Check the water inlet filter every day.
The dirt trap in the pressure reducer should be taken out and cleaned at
least once every two weeks or replaced if necessary.
.
Bei jedem Motorenservice sollte das Getriebeöl kontrolliert werden, notfalls
das Getriebeöl erneuern.
Die Füllmenge siehe Typenschild.