Mixing pump RITMO L plus FC-230V Overview Operation
Sound power level
2020-11-09 11
6.6 Compressor DT4.8
Specification Value
Unit
Compressor output 0.080
Nm³/min
6.7 Operating requirements
Ambient conditions
Specification Value
Unit
Temperature range 2 - 45
°C
Relative humidity (maximum) 80
%
Operating period
Specification Value
Unit
Maximum continuous operating period
8
hours
6.8 Connection values for water
Fig. 1: Water connection
Specification Value
Unit
Operating pressure, min. 2.5
bar
Connection 1/2
inches
7 Sound power level
Guaranteed sound power level LWA 78 dB (A)
8 Vibrations
Weighted effective acceleration value to which the upper limbs are exposed = < 2.5 m/s²
9
EMC test
The machine has been EMC tested and complies with the strict requirements of EMC Directive filter class B.