51.5 Table of malfunctions
Malfunction Possible cause Solution Performed by
Machine does
not start
Water
Water pressure too low Check the water supply,
clean the dirt trap screens
Operator
Gauge displays pressure
below 2.2 bar
Check pressure booster pump Service technician
Machine does
not start
Power
Power cable is defective Repair the power cable Service technician
Main switch not activated Turn on the main switch Operator
FI circuit breaker triggered Reset the FI circuit breaker Service technician
Motor protection switch triggered Turn the motor protection switch to
the position “1” in the control box
Service technician
Contactor is defective Replace the contactor Service technician
Fuse is defective Replace the fuse Service technician
Machine does
not start Air
Insufficient pressure gradient in
remote control due to blocked
air line or air nozzle tube
Clean blocked air pipe or air
nozzle tube
Operator
Air safety switch incorrectly set Adjust air safety switch Service technician
Air compressor not connected Connect air compressor Operator
Machine does
not start
Material
Too much thickened material in
the hopper or mixing area
Half-empty the hopper and
restart it.
Operator
Material in pump component
too dry
Allow the machine to run
backwards, otherwise
remove pump and clean it
Service technician