Applying mortar
42 2020-11-09
45.2 Interruption of work
NOTE!
Generally, the setting times of the materials to be
processed must be observed:
Clean the equipment and hoses as appropriate for
the setting time of the material and the length of
the interruption (take outdoor temperature into
account).
Observe the guidelines of the material
manufacturer regarding interruptions.
1
Fig. 81: Closing the air valve
1. For brief work interruptions, close the air valve (1).
2. The machine stops.
3. By opening the air valve (1), the machine will start running again.
45.3 In the event of a work stoppage / pause
1
Fig. 82: Closing the air valve
Fig. 83: Switching off
1. Close the air valve (1).
2. Turn the selector switch (2) to the “Zero” position
(middle position).
2