Mixing pump RITMO L / RITMO M Overview - Operation
Preparing the machine
2016-02-17
33
Fig. 38: Connecting the water
5. Check whether the water inlet sieve in the water inlet (3) is
clean.
6. Clean the water hose (4) from the water supply network and
bleed.
7. Connect the water hose (4) to the water inlet (3).
8. Remove the water hose (5) from the mixing tube.
NOTE!
Use only clean water free of solids. The minimum
pressure is 2.5 bar when the machine is running.
Pay attention to the Drinking Water Ordinance in
part 1.
NOTE!
Never let the pump run dry as this reduces the
service life of the pump.
25.3 Connection of water from water tank
Fig. 39: Booster pump
Fig. 40: Suction strainer with filter screen
coupl.
Booster pump AV3000/1 (1) Article number 00493686
The connected booster pump ensures the required water pressure
of at least 2.5 bar.
NOTE!
When working from the water tank, the strainer
with filter screen (article number 00136619) has to
be positioned upstream (bleed booster pump).
NOTE!
Never let the booster pump run dry as this reduces
the service life of the pump significantly.
5
3
4
1