4-18
Figure 39: Uniform Voltage Step Results Test Sample Printout
Figure 39 shows a sample printout of a Uniform Voltage Step Test. This printout reflects the results of a Step
Test of 5-minute duration, 15kV max output voltage, and 20 steps of voltage at a uniform 15-second duration
each.