The test standard condition :Brightness control is at 100 contrast control is at 50
8.13
Distance between TFT
LCD monitor and CRT/TFT monitor
Conducted with different modes
or frequencies.
No interference in a distance down to 25 cm.
9.
ENVIRONMENT
(EE)
9.1
Environmental characteristics
The following sections define the interference and susceptibility condition limits
that might occur between external
environment
and the display device.
Operating:
- Temperature :
5°C to 40°C
- Humidity :
20% to 80%
- Altitude :
0 to 5000 M
Storage:
- Temperature : -20 to 60 degree C
- Humidity
:
10% to 80%
- Altitude
:
0 to 12000M
Note: recommend at 5 to
35
q
C, Humidity less
than 60 %
10.
REGULATORY STANDARDS
(Safety)
Note:
All certificates must be raised under the
name of Philips
10.1
Safety approvals
;
CB report
;
CE
10.2
Power management
;
Energy Star
10.3
Certificates, Reports for the production start
When the first production
of the monitor starts
the following documents must be sent to Philips by mail. All reports
must be raised under “Philips”
and have to
show W0ZR model name .
;
CB report
;
CE
;
FCC
;
Service manual
11
RELIABILITY
(EE)
11.1 Reliability of the monitor
The MTBF of
the monitor has to be greater than 50.000 hours.
12. CUSTOMIZATION
(PM)
12.1 Identity Customization
Refer to SKU
12.2 EAN /SAP Identification