10
SimplyGo User Manual
Getting Started
Attach the shoulder strap to the carrying case�
Before using the SimplyGo device for the rst time, the SimplyGo battery
requires an initial uninterrupted charging time of 4 hours minimum� This can
be accomplished by installing the battery and using the AC Power Cord, as
described in the following pages� Or optionally, you can use the external
battery charger (sold separately) to charge the SimplyGo batteries�
Note: Philips Respironics does not recommend using DC power for this initial
charging
Caution: Use only Philips Respironics batteries in your SimplyGo device
Using other batteries could damage the device and will void the
warranty� Remove the battery if the SimplyGo will not be used for an
extended period of time�
Battery Duration Times
SimplyGos battery times vary depending on which operating mode (Pulse or
Continuous Flow) is being used and which setting is selected in the operating
mode� SimplyGo is designed to allow easy access to the battery so that it is
easy to swap out and utilize extra batteries (sold separately) as needed� Extra
batteries t easily into the zippered pouch of the carrying case or in the handy
accessories bag� Additionally, extra batteries can be charged in the external
battery charger (sold separately) or in the SimplyGo device (see the “Charging
the Battery with the AC Power Supply” section), allowing maximum exibility
to meet your specic battery needs�
The following shows the approximate battery durations for Pulse ow settings
at 20 BPM and Continuous Flow settings when the battery is fully charged�*
Your times may vary based on your activity level, the condition of the
batteries, and the age of your SimplyGo device�
PulSe doSe SeTTing ConTinuouS Flow SeTTing
1 2 3 4 5 6 0�5 1 2
3�4
hours
3�0
hours
2�2
hours
1�7
hours
1�3
hours
1�3
hours
2�9
hours
1�6
hours
0�9
hours
* Battery Duration times are based on new, fully charged batteries used
with a new SimplyGo system� Battery duration times will degrade with
battery age, environmental operating conditions, use over time, and
operational condition of the concentrator� If the battery is near the end
of its useful life, you may experience battery durations of approximately
two-thirds that of a new battery

Table of Contents

Other manuals for Philips Respironics SimplyGo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips Respironics SimplyGo and is the answer not in the manual?

Philips Respironics SimplyGo Specifications

General IconGeneral
Weight10 lbs (4.5 kg) with battery
Continuous Flow Setting0.5, 1, 1.5, 2 LPM
Operating Temperature41°F to 104°F (5°C to 40°C)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Oxygen FlowContinuous Flow and Pulse Dose
Pulse Dose Setting1, 2, 3, 4, 5, 6
Power SourceAC/DC power supply, rechargeable battery
Dimensions11.5 in x 10 in x 6 in
Operating ModesContinuous flow, pulse dose
Battery TypeLithium Ion
AC Power Input100-240 VAC, 50/60 Hz
DC Power Input11.5 to 16 VDC
Humidity Range15% to 95% non-condensing
Altitude RangeUp to 10, 000 ft (3048 m)
Warranty3 years