2.0 INSTALLATION AND RECOMMENDATIONS
2.1 Recommendations
The pump must be installed far from a heat source, in a dry place at a maximum ambient temperature
of 40°C. The minimum operating temperature depends on the liquid to be dosed, which must always
remain fluid.
The pump must be installed in a place where it cannot be flooded
Electrical installation must comply with national standards in force in the various countries.
In France, the NFC 15-100 standard must be complied with.
A means of disconnection from the power supply network must be present, and must have a contact
opening distance of all poles ensuring complete disconnection under overvoltage category III conditions.
2.2 Hydraulic and electrical installation
L: Filtration pump already installed on your system, designed to circulate the water drawn from your pool
to the filtration system.
M: Electrical box already present on your installation, designed to control your entire filtration system.
N: Cable without plug intended to be connected in the pool electrical box “M” to terminals A1 and A2 in
parallel with the relay coil of the filtration pump “L”.
The voltage to be applied to this cable is 230V - 240V. This means the unit will only be powered when the
filtration pump is running.
Power supply: 230V - 240V Power: 10W
Max flow: 1,5 l/h Max pressure: 1,5 bars (150 000 Pa)
Fig.3
N
M: Inside of the pool's
electrical box
A1
A2

Table of Contents