Instruction and Operator's Manual PICO pH
5
Caution:
• Under no circumstances should the device be connected in parallel with the power supply terminals
of the “L” filtration pump in the “M” electrical box.
• The injection point “H” must be placed last on the hydraulic system (as shown in the diagram).
• When installing a redox regulator with a pH regulator, it is advisable to position the two probes side-
by-side and the acid pH injector before the chlorine injector, to minimize scale build-up on the
chlorine injector.
• For optimum durability of your peristaltic tube, it is preferable not to exceed a pressure of 1 bar, and
under no circumstances to exceed a pressure of 1.5 bar (150,000 Pa).
• The pH sensor should be located before the chlorine injection point, the cell of an electrolyzer and
the heater (in the direction of flow).
2.3 Accessory assembly
2.3.1 Dimensions of PICO pH
2.3.2 Clip’Easy Dimensions