7 Operation
7.1 Messages
Whenthesupplyvoltageisswitchedon,thePNOZmultisafetysystemcopiestheconfigur
ationfromthechipcard.
TheLEDs“POWER”,“DIAG”,“FAULT”,“IFAULT”and“OFAULT”willlightuponthebase
unit.
TheexpansionmodulePNOZmESProfinetisconfiguredandstartedautomatically.The
LEDs"RUN"and"ERR"displaythestatusofthePNOZmESProfinetatthePROFINET.
IftheexpansionmodulePNOZmESProfinetdoesnotreceiveaconfigurationfromthe
baseunitforaperiodof30s,theexpansionmodulePNOZmESProfinetconnectstothe
IOcontrollerand"RUN"statusisdisplayedonPROFINET.Theerrormessage"NoCon
nectionwithBaseModule"issenttotheIOcontroller.
Legend:
LEDon
LEDflashes
LEDoff
LED Meaning
Power Green Supplyvoltageispresent
Supplyvoltageisnotpresent
Run Green TheconnectiontotheIOcontrollerisestablished,theIOcontrollerisin
RUNcondition
green,1x TheconnectiontotheIOcontrollerisestablished,theIOcontrollerisin
STOPcondition
Green Deviceidentification(LED"Diag"alsoflashesgreen)
NoconnectiontoIOcontroller
Diag Red Diagnosticdataavailable(maintenancerequiredorerror)
Green Deviceidentification(LED"Run"alsoflashesgreen)
Red Nodevicenameassigned