PNOZ XV1P
Operating Manual PNOZ XV1P
20596-EN-07
8
Unit features
} Positive-guided relay outputs:
– 2 safety contacts (N/O), instantaneous
– 1 safety contact (N/O), delay-on de-energisation
} Connection options for:
– E-STOP pushbuttons
– Safety gate limit switches
– Start buttons
– Light grids and safety switches with detection of shorts across contacts
} Selectable delay time
} LED display for:
– Supply voltage
– Switch status of the safety contacts
} Plug-in connection terminals (either spring-loaded terminal or screw terminal)
} See order reference for unit types
Safety features
The safety relay meets the following safety requirements:
} The circuit is redundant with built-in self-monitoring.
} The safety function remains effective in the case of a component failure.
} The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.
Block diagram/terminal configuration
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)