Do you have a question about the Pilz PNOZ XV3.1P and is the answer not in the manual?
| Rated Control Supply Voltage | 24 V DC |
|---|---|
| Category | 4 |
| PL | e |
| SILCL | 3 |
| Number of Safety Contacts | 3 |
| Protection Class | IP20 |
| Standards | EN 60947-5-1, EN 60204-1, EN ISO 13849-1, EN 62061, IEC 61508 |
Specifies the validity and usage guidelines for the product's operating manual.
Explains hazard symbols (DANGER, WARNING, CAUTION, NOTICE) for safety communication.
Covers product's intended use, safety regulations, and assessment requirements.
Details requirements for qualified personnel, warranty, liability, and product disposal.
Lists relay outputs, connection options, and LED indicators of the PNOZ XV3.1P.
Explains the safety features like redundancy and self-monitoring for functional safety.
Illustrates block diagrams and terminal configurations for AC/DC and DC voltage types.
Details input circuit operation, modes, delay, and reset functions.
Presents timing diagrams and explains key timing parameters like delays and recovery times.
Provides instructions for mounting the unit in control cabinets and on DIN rails.
Offers important notes on wiring, terminal connections, and EMC compliance.
Shows wiring diagrams for E-STOP and safety gate inputs in single and dual-channel setups.
Details start circuit wiring and procedures for shorts detection testing.
Covers reset delay, feedback loop, and essential operational checks for safety.
Explains the meaning of each LED indicator for status and error reporting.
Describes common faults, interference issues, and troubleshooting tips.
Provides the physical dimensions of the unit in millimeters.
Covers certifications, voltage, power, input parameters, and cable resistance.
Details relay outputs, utilisation categories, UL specs, fuse protection, and contact material.
Provides data on thermal current, timing parameters, environmental suitability, and mechanical aspects.
Covers certifications, voltage, power, input parameters, and cable resistance.
Details relay outputs, utilisation categories, UL specs, fuse protection, and contact material.
Provides data on thermal current, timing parameters, environmental suitability, and mechanical aspects.
Covers certifications, voltage, power, input parameters, and cable resistance.
Details relay outputs, utilisation categories, UL specs, fuse protection, and contact material.
Provides data on thermal current, timing parameters, environmental suitability, and mechanical aspects.
Covers certifications, voltage, power, input parameters, and cable resistance.
Details relay outputs, utilisation categories, UL specs, fuse protection, and contact material.
Provides data on thermal current, timing parameters, environmental suitability, and mechanical aspects.
Details safety parameters (PL, SIL CL, PFH) and provides explanatory notes for their use.
Presents service life graphs and explains how to use them for application calculations.
Provides step-by-step instructions with an image for safely removing plug-in terminals.
Lists product types, features, connection types, and corresponding order numbers.
States compliance with EU Machinery Directive and provides a link for the full declaration.
Provides contact information for technical support across various global regions.
Highlights Pilz's commitment to environmentally friendly products and energy-saving technologies.