PNOZ XV3.1P
Operating Manual PNOZ XV3.1P
20516-EN-09
| 27
Conventional thermal
current while loading
several contacts
777530 777532 777538
Ith per contact at UB AC;
AC1:240V,DC1:24V
Conv. therm. current
with 1 contact 8 A 8 A 8 A
Conv. therm. current
with 2 contacts 7,8 A 7,8 A 7,8 A
Conv. therm. current
with 3 contacts 6,5 A 6,5 A 6,5 A
Conv. therm. current
with 4 contacts 5,5 A 5,5 A 5,5 A
Conv. therm. current
with 5 contacts 5 A 5 A 5 A
Ith per contact at UB DC;
AC1:240V,DC1:24V
Conv. therm. current
with 1 contact 8 A 8 A 8 A
Conv. therm. current
with 2 contacts 7,8 A 7,8 A 7,8 A
Conv. therm. current
with 3 contacts 6,5 A 6,5 A 6,5 A
Conv. therm. current
with 4 contacts 5,5 A 5,5 A 5,5 A
Conv. therm. current
with 5 contacts 5 A 5 A 5 A
Times 777530 777532 777538
Switch-on delay
With automatic start
typ. 400 ms 400 ms 400 ms
With automatic start
max. 550 ms 550 ms 550 ms
With automatic start
after power on typ. 750 ms 750 ms 750 ms
With automatic start
after power on max. 1.050 ms 1.050 ms 1.050 ms
With monitored start
typ. 35 ms 35 ms 35 ms
With monitored start
max. 60 ms 60 ms 60 ms