PNOZ XV3.1
Operating Manual PNOZ XV3.1
20515-EN-08
| 7
Unit features
} Positive-guided relay outputs:
– 3 safety contacts (N/O), instantaneous
– 2 safety contacts (N/O), delay-on de-energisation
– 1 auxiliary contact (N/C), instantaneous
} Connection options for:
– E-STOP pushbutton
– Safety gate limit switch
– Start button
} Delay time fixed or selectable
} Possible to cancel delay time
} LED display for:
– Supply voltage
– Switch state of the safety contacts
– Start circuit
} See order reference for unit types
Safety features
The safety relay meets the following safety requirements:
} The circuit is redundant with built-in self-monitoring.
} The safety function remains effective in the case of a component failure.
} The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.