PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05
14
NOTICE
Operation with a light guard or safety switch
It must not be possible to switch off the supply voltage for the PNOZ XV3P
separately from the supply voltage for the light guard or safety switch.
Start circuit
E-STOP wiring
Safety gate without start-up
test Safety gate with start-up test
Automatic start
Simultaneity S1 and S2: max. 3 s
Monitored start
NOTICE
In the event of an automatic start:
The unit starts up automatically when the safeguard is reset, e.g. when the
E-STOP pushbutton is released. Use external circuit measures to prevent
an unexpected restart.
Reset delay time Without reset With reset
Link or N/C contact
Feedback loop Automatic start Monitored start
Contacts from external contactors
K5
K6
K5
L1
N
K6
S13
13 (23, 33)
S14
14 (24, 34)